Well ,new Reg installed ,same one as before VR-115 . With the Reg hooked (connected) up I test voltage
on brown and get approx 12 volts BUT when I test the Green wire going out I get 11 Volts. same at the positive brush . I loose a full Volt ! My ground is good to Reg (zero ohms) .I have already tested and confirmed that
battery voltage and the brown wire to Reg (Reg not connected) is same voltage. Im losing approx .03 Volts.
Im stumped. 5T u have the same Reg on a 78 I think with separate Rec, if u test green and brown at Reg with everything connected and running what voltage do u get in and out. The New Reg is working same as old unit, if I raise rpm to approx 2500 it will read
14.2 volts at battery and go no higher, u can see it cut voltage back as soon as it gets to a certain rpm. Is it possible that the Reg is putting out a lower voltage until it sees the battery is at
full charge, reaching here.
I think if I leave it this way ,im going to damage new rotor !